Manitowoc Ice QF2200, QF2300, QF0800, QC0700 Electrical System, Section, Energized Parts Charts

Models: QF2200 QF0400 QC0700 QF0800 QF2300

1 150
Download 150 pages 297 b
Page 64
Image 64
Electrical System

Electrical System

 

 

 

 

 

 

 

 

Section 6

 

 

 

 

 

 

 

 

 

 

Energized Parts Charts

 

 

 

 

 

 

 

QF2200

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ice Making

 

Control Relays

 

 

Sensors

 

 

 

 

 

 

 

 

 

 

 

 

1

 

2

3

4

 

 

 

 

Length

Sequence

 

Water

 

 

Gear

 

 

 

 

 

Bin Level

Temperature

Liquid Line

 

 

Float

Of

Dump

Gear

Level

Motor

Of Time

Solenoid

 

Valve

Probe

Sensor

Operation

 

Valve

Motor

Probe

Speed

 

Valve

 

Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

START-UP

 

 

 

 

 

Not

 

Not Sensing

Sensing

 

 

 

 

 

 

Sensing No

for Gear

 

1A. Water

Off

 

On

On

Off

Sensing for

for

45 Seconds

 

Ice Contact

Motor

Flush

 

 

 

 

 

Water Level

Temperature

 

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

 

Not Sensing

Sensing

Until Water

1B. Water

 

 

 

 

 

Sensing for

Sensing No

for Gear

Contacts

Off

 

Off

On

On

for

Fill

 

Water Level

Ice Contact

Motor

Water Level

 

 

 

 

 

Temperature

 

 

 

 

 

 

 

 

Speed

Probe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sensing for

 

Until Ice

 

 

 

 

 

 

 

 

123°F

 

 

 

 

 

 

 

 

 

Sensing

Contacts Bin

FREEZE

 

 

 

 

 

 

 

Immediately.

 

 

 

 

 

Sensing for

Sensing No

for Gear

Level Probe

SEQUENCE

On

 

Off

On

On

Sensing for

 

Water Level

Ice Contact

Motor

for 30

2. Freeze

 

 

 

 

 

30°F after 30

 

 

 

 

 

 

 

Speed

Continuous

 

 

 

 

 

 

 

 

min. of Ice

 

 

 

 

 

 

 

 

 

Seconds

 

 

 

 

 

 

 

 

Making

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AUTOMATIC

 

 

 

 

 

 

 

Not Sensing

Sensing

 

SHUT-OFF

 

 

 

 

 

Sensing for

Sensing

for Gear

 

Off

 

Off

On

On

for

4 Minutes

3A. Ice Run

 

Water Level

Ice Contact

Motor

 

 

 

 

 

Temperature

 

Out

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

 

3B. Drain

Off

 

On

Off

Off

Not

Sensing

Not Sensing

Sensing

90 Seconds

 

Sensing for

for

for Gear

Evaporator

 

Ice Contact

 

 

 

 

 

Water Level

Temperature

Motor

 

 

 

 

 

 

 

 

 

 

Speed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Not

Until Ice No

 

 

 

 

 

 

Not

 

Not Sensing

Sensing

AUTOMATIC

 

 

 

 

 

Sensing

Longer

Off

 

Off

Off

Off

Sensing for

for

for Gear

SHUT-OFF

 

Ice Contact

Contacts Bin

 

 

 

 

 

Water Level

Temperature

Motor

 

 

 

 

 

 

 

 

 

Speed

Level Probe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*After the liquid line solenoid valve energizes, the suction pressure will rise above the low-pressure switch cut-in (22 psig) and the compressor and condenser fan motor energize. The condenser fan motor remains energized during the entire freeze cycle, the head pressure control valve con- trols the discharge pressure.

When the toggle switch is placed in the ICE position, the following must occur prior to starting an ice making cycle.

A.)The bin level probe must be open (Bin Level light off). If the probe is closed (Bin Level light on) when the toggle switch is moved to ICE, the control system waits until the bin level probe opens (Bin Level light off) before starting an ice making sequence.

If the bin level probe is disconnected from the control board, the ice machine will not start and will continuously flash the Bin Level light. The ice machine will remain off until:

1.The bin level probe is reconnected to the circuit board

2.The toggle switch is moved from ICE to OFF, then back to ICE.

B. The water level probe must be closed (Water Level light on) to start the compressor.

If the water level probe is open (Water Level light off), the control system waits until the water level probe closes before starting the compressor.

8-Minute Lockout - The Bin Level light will flash until the 8-minute lockout expires. After the 8-minute lockout expires, the Bin Level light will de-energize.

The 8-minute lockout time can be overridden by moving the ICE/OFF/CLEAN toggle switch from ICE to OFF, then back to ICE.

6-2

Revised 8/2003

Part No. 80-1214-3

 

 

Page 64
Image 64
Manitowoc Ice QF2200, QF2300, QF0800, QC0700, QF0400 service manual Electrical System, Section, Energized Parts Charts