10 Chapter 1: Introduction
Matrox Meteor-II boards
Matrox Meteor-II comes in four versions: Matrox Meteor-II /Standard, Matrox Meteor-II /Multi-Channel, Matrox Meteor-II /Digital, and Matrox Meteor-II /1394. Some of these boards are available in different form factors, namely PCI, CompactPCI, and PC/104-Plus. All boards and form factors support real time image transfer to Host memory, and can be programmed with the Matrox Imaging Library (MIL) or any of its derivatives.
Matrox Meteor-II /Standard
Matrox Meteor-II /Standard is a standard monochrome and color analog frame grabber. This board is available in a PCI, PC/104-Plus, or CompactPCI (3U) form factor, all of which can use a Matrox Meteor-II MJPEG module for compression and decompression of monochrome and color images.
BNC Connector for PCI and Compact PCI form factors 
VMChannel (not available on CompactPCI and PC/104-Plus)
To DB-44 Connector for PCI and Compact PCI form factors
To 30-pin male, right-angle connector for PC/104-Plus form factor
Not available on CompactPCI form factor
VID_IN1 | | | | | | | | | | | | | | Low | | | | | | | |
| | | | | | | | | | | | | | | |
VID_IN2 | | | | | | | | | | | | | | Pass | | | | Gain Decoder | | |
| | | | | | | | | | | | | | | | | |
VID_IN3 | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | Filter | | | | | | | |
VID_IN4 | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | |
VID_IN5 | | | | | | | | | | 12:1 | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | |
VID_IN6 | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | MUX | | | | | | | |
VID_IN7 | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | |
VID_IN8 | | | | | | | | | | | | | | | | | | | | | | | | | |
VID_IN9 | | | | | | | | | | | | | | | | | | | | | | | | | |
VID_IN10 | | | | | | | | | | | | | | | | | | | | | | | |
VID_IN11 | | | | | | | | | | | | | | | | | | | | | | | |
VID_IN12 | | | | | | | | | | | | | | | | | | | | | | | |
Trigger | | | | | | | | | | | | | | | | | Opto- | | | |
Aux | { | | | | | | | | | 2 | | | | | | | | coupler | | | |
| | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | 2 | | | | | | | | | | | | |
RX | | | | | | | | | | | | | | | | | | | | |
| | | | | | RS-232 | | | | | | | | | | | |
| | | | | | | | | | | | | | | | |
TX | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | |
/RTS | | | | drivers & | | | | | UART | | | | |
| | | | | | | | | | | | |
/CTS | | | | receivers | | | | | | | | | |
| | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | |
| | | | | | | | | | | | | | | | | | | | | | | | | |
MJPEG
Module
(optional)
64
SGRAM (4 Mbytes)
| Not available on PC/104-Plus | Host 32-bit PCI bus |
| form factor |
| |