92 Appendix B: Technical information Matrox
Jumper
1 | 2 | 3 |
pin | pin | pin |
Side view
As shown in the table below, place the jumper across pins 1 and 2 for a +5 V supply output and across pins 2 and 3 for a +12 V supply output.
Pin | Description |
|
|
+5 V (default) | |
|
|
+12 V | |
|
|
By default, auxiliary power supply is strapped for +5 V (pins
Specifications
Electrical
Form Factor | Operating Voltage and current |
| Power | ||||
|
|
|
|
|
|
| Consumptiona |
|
| 5 V ±5% | 3.3 V ±5% | 12 V ±10% |
| ||
|
|
|
|
|
|
|
|
PCI and | 1.25 A | n/a | n/a | 250 mA | 50 mA | 9.85 W | |
CompactPCI |
|
|
|
|
|
| |
|
|
|
|
|
|
| |
100 mA | 25 mA | 1.1 A | 150 mA | n/a | 6.06 W | ||
|
|
|
|
|
|
|
|
a.This number represents the total power consumption of the Matrox
Environmental
■Min./max. ambient operating temperature: 0°C - 55° C.
■Min./max. storage temperature:
■Max. altitude for operation: 3000 meters.
■Max. altitude for transport: 12000 meters.
■Operating humidity: 20 - 80% relative humidity