This chapter explains how to run Autotest, including selecting the cable types and Autotest specifications. It also explains how to customize an Autotest so you can select the pairs that are tested, the PASS/FAIL criteria, and select which tests to run during Autotest. Each test, such as NEXT, Impedance, Capacitance, etc. is explained, including how to customize the limits for each test and how to troubleshoot test results.

Steps for Running Autotest

1.From the Ready screen, verify that the cable type matches the cable type you will be testing. If it matches, proceed to step 2. Otherwise, see Selecting the Cable Type for instructions.

2.Also from the Ready screen, verify that the default Autotest is the Autotest that you want to run. If it is, proceed to step 3. Otherwise, see Customizing Autotest for instructions.

3.Connect the Scanner to the near end of the twisted pair cable you are testing and connect the Injector to the far end. During Autotest, the Injector provides the far end termination for measurements made by the Scanner. In addition, it generates signals of programmable frequency for measurement by the Scanner to determine one-way Attenuation. The 2-WayInjector+/2-Way Injector also generates swept frequency signals and measures the Near End Crosstalk at its end of the installed link. The Scanner acts as the termination device while NEXT is being measured by the 2-WayInjector+/2-Way Injector.

4.If you have not used the Injector in the last 24 hours, you will need to calibrate. Press the

Extended Functions key and select Calibrate Injector.

5.Press the AUTOTEST key. If you are testing twisted pair cable, the Scanner will immediately verify that the Injector is attached. If the Injector is not attached, the Scanner will wait until it is attached before running the Autotest.

6.When the Autotest completes, a PASS or FAIL tone will sound. You can then view the results of individual tests. (See Autotest Results Screen for instructions.) Or, you can view a summary of test results. (See Viewing Autotest Results Summary for instructions.)

7.You can also save Autotest results — see Saving Autotest Results for details.

8.You can also print Autotest results — see Printing Autotest Results for details. A sample Autotest report is shown at the end of this chapter.

Press the ESCAPE key at any time to cancel the Autotest.

Selecting the Cable Type

To display the CABLE SETUP screen, press Cable (F1) from the Ready screen. This screen displays the cable types available for testing.

Before running an Autotest, verify that the cable type you are testing matches the cable type in the Scanner. Press the or arrow key to scroll through the list one line at a time. Press the or arrow key to scroll through the list one page at a time.

If the cable type you are using is not in the list, press Edit (F2) to define a new cable type (see Editing the Cable Type for further instructions). You can also press Edit (F2) to review the current settings for the selected cable type or to make changes.

Press Default (F1) to choose the highlighted cable type for the test you run. Choosing the correct cable type will ensure accurate Length measurements.

Press Delete (F3) to delete user-defined cable types. Note: Factory-supplied cable types cannot be deleted.

Page 14
Image 14