High Voltage Protection
The PentaScanner+/PentaScanner/PentaScanner Cable Admin,
Injector and Super Injector+/Super Injector are designed to withstand input hazard voltage conditions that arise from normal telephony applications such as 48 VDC at less than 80 ma or 24 VAC used to power many keysets. The unit detects when a voltage of greater than ±15 volts is applied on the inputs and sounds a warning to alert the user to remove the hazard condition immediately to prevent possible damage to the input circuits. Tests cannot be performed when hazard conditions are detected on the inputs.
2-Way Injector+/2-Way Injector LED Indicators
Test Connector
Pass
Indicator
Status
Indicator
Fail
Indicator
Circuit
Guard
Indicator
Charging
Indicator
Indicator | State | Description | |
Pass | Steady Light | Overall Autotest result is PASS | |
Fail | Steady Light | Overall Autotest result is FAIL | |
Status | Steady Light | The Injector is powered ON and waiting for | |
|
| communication with the Scanner. | |
Status | Off | The Injector is powered OFF (or charging battery | |
|
| if AC adapter is attached). | |
Status | Rapid Blink | Executing command or measurement in progress | |
|
|
|