Injector

 

Measurement

Required?

Description

Attenuation

Yes

The Injector generates the frequencies and the Scanner

 

 

measures the signal to determine the signal loss.

Autotest

Yes

The Injector is required for Attenuation, NEXT

 

 

measurements, Resistance and Wire Map during Autotest.

Capacitance

No

If connected, the Injector provides an “OPEN” for the

 

 

duration of the measurement.

Length

No

If connected, the injector provides an “OPEN” for the

 

 

duration of the measurement.

Impedance

No

If connected, the injector provides an “OPEN” for the

 

 

duration of the measurement.

NEXT - Scanner

Yes

The Injector provides a 100 ohm termination while the

End

 

Scanner measures NEXT.

NEXT - Injector

Yes

The Scanner provides a 100 ohm termination for the

End (2-Way

 

duration of the measurement.

Injector+/2-Way

 

 

Injector only)

 

 

Loop Resistance

Yes

If connected, the Injector is used to “SHORT” the wire pair

 

 

under test and the Scanner measures Loop Resistance. If the

 

 

2-Way Injector is not connected, the Scanner will display

 

 

“OVR” (Over Range).

Wire Map (Find

Yes

The Scanner communicates with the Injector across the link

Cable Faults)

 

under test to determine the wire connection from the

 

 

Scanner end to the Injector end.

Noise

No

The Injector is not required to measure impulse noise or

 

 

peak-to-peak noise.

Note: The Injector is not used when testing coaxial cable. See Appendix D: Working with Coaxial Cable for more information.

Using Multiple Injectors

One Scanner can store calibration data for up to five Injectors. To determine which Injector is attached to the Scanner, press the Extended Functions key, then select Injector Info. The Scanner will display the serial number and other information for the attached Injector.

Injector Calibration

Calibration of the Injector’s signal amplitude is required for accurate Attenuation measurements and requires user intervention. To maintain accurate Attenuation measurements, the Injector must