Resistance is said to fail if measured values on pairs used by the selected network type are greater than the resistance for a maximum length loop (100 meters for most networks).

Customizing Loop Resistance Limits

To display the LOOP RESISTANCE LIMITS screen, press the Extended Functions key, then select Setup Autotest, then highlight the Autotest to edit, then press Edit (F2), then select Limits, then select Loop Resistance. This screen lets you change the maximum Loop Resistance limit.

If your Scanner has an alphanumeric overlay on the keypad, use the keypad to enter the limit. If your Scanner does not have an alphanumeric overlay, press Edit (F2) to display the edit screen.

After editing, press Save (F1) to store the new maximum Loop Resistance limit and exit or press the ESCAPE key to exit without saving.

Loop Resistance Test Results

To display the LOOP RESISTANCE screen, press View (F1) from the AUTOTEST RESULTS screen, then press the Ä key until the LOOP RESISTANCE screen is displayed.

At the upper left of the screen, the pair corresponding to the test result is shown. The Loop Resistance, in ohms (Ω), is shown to the right of the pair. The PASS/FAIL bar across the screen compares the measured Loop Resistance value to the Loop Resistance limit value. Below the PASS/FAIL bar, the Loop Resistance limit value is displayed. The Autotest name is displayed after Spec: at the lower left of the screen.

Press Table (F1) to display the Loop Resistance test results for all pairs or press Pair (F3) to toggle through the Loop Resistance results for each pair.

Press the or arrow key to display the previous or next test results screen. Press the ESCAPE key to return to the AUTOTEST RESULTS screen.

Note: For diagnostic purposes, you can run Loop Resistance continuously by pressing the Measure Cable Performance key and selecting Loop Resistance.

Capacitance

Capacitance is the amount of electric field energy that can be stored between two conductors at a given voltage. For twisted pair cable, Capacitance is measured between conductors in a pair. For coaxial cable, Capacitance is measured between the conductor and the shield.

The Capacitance measurement is made by measuring the effective charging and discharging time constant that is formed by the capacitance of the cable. This is done at low frequency to eliminate any transmission line effects of the cable under test.

Customizing Capacitance Limits

To display this screen, press the Extended Functions key, then select Setup Autotest, then highlight the Autotest to edit, then press Edit (F2), then select Limits, then select Capacitance.

Press the or arrow key to select the minimum or maximum Capacitance limit. The selected limit will be enclosed in a box.

Page 28
Image 28
Microtest TSB-67 - 568A Annex E manual Customizing Loop Resistance Limits, Loop Resistance Test Results, Capacitance