Maintenance Chapter 6
Replacing the Toner Cartridge
To Reset the Counter of the Toner Cartridge
Perform the following procedure to reset the toner cartridge counter after you replace the toner cartridge.
1
2 Keep the panel button held down, and the Ready indicator will start to blink. After the Ready indicator has blinked for about 5 seconds, release the panel button. This should cause all the indicators to start to blink.
3 After confirming that all the indicators are blinking, press and hold down the panel button again for at least 5 seconds. During this time, the Ready indicator only continues to blink and all the other indicators turn off.
4 Release the panel button and only the Paper indicator starts to blink.
5 After a few seconds, all the indicators start to blink again, indi- cating that the toner cartridge counter has been reset.
6 Turn off the printer. The printer will be ready to print the next time you turn it on.