Motorola MVME2400 manual Status Indicators, 10/100 Baset Port, PMC2 DS3, PMC1 DS4

Models: MVME2400

1 178
Download 178 pages 33.7 Kb
Page 44
Image 44

Operating Instructions

Status Indicators

There are four LED (light-emitting diode) status indicators located on the MVME240x front panel.: BFL, CPU, PMC2, and PMC1.

BFL (DS1)

The yellow BFL LED indicates board failure; lights when the BRDFAIL* signal line is active.

CPU (DS2)

The green CPU LED indicates CPU activity; lights when the DBB* (Data Bus Busy) signal line on the processor bus is active.

PMC2 (DS3)

The top green PMC LED indicates PCI activity; lights when the PCI bus grant to PMC2 signal line on the PCI bus is active. This indicates that a PMC installed on slot 2 is active.

PMC1 (DS4)

The bottom green PMC LED indicates PCI activity; lights when the PCI bus grant to PMC1 signal line on the PCI bus is active. This indicates that a PMC installed on slot 1 is active.

10/100 BASET Port

The RJ45 port on the front panel of the MVME240x labeled 10/100 BASET supplies the Ethernet LAN 10BaseT/100Base TX interface, implemented with a DEC 21140/21143 device.

MVME

240x

DEBUG

ABT

BFL

CPU

RST

PMC

10/100 BASET

PCI MEZZANINE CARD

PCI MEZZANINE CARD

2-4

Computer Group Literature Center Web Site

Page 44