Chapter 5

VisuaLink 128/384 User Guide

The setting screen is displayed. The current setting is displayed.

 

MLP Speed

:

< 4.0kb/s >

 

 

 

LSD speed

:

< 1.2kb/s >

 

 

 

Serial port setting

 

 

 

 

 

 

Port 1

:

<

Camera >

 

 

Port 2

:

<

Console

>

 

 

User port speed

:

<

9.6kb/s

>

 

 

T120 port speed

:

<

38.4kb/s

>

 

 

Console speed

:

<

9.6kb/s

>

 

 

Console parity

:

< 8 bit none >

 

 

Press ENTER after choosing.

 

 

 

 

 

 

MLP:

Multi Layer data sets the speed for NEC far-end control.

 

Note: MLP must be active in order to upgrade VL system

 

on-line.

 

 

 

 

 

LSD:

Low Speed data sets the speed for far-end camera control.

Serial port setting:

Sets the type of control to be activated on the serial port.

User port speed:

Sets the data transmission rate for a point-to-point

 

environment.

 

 

 

 

 

T120 port speed:

Sets the data transmission rate for a multipoint

 

environment.

 

 

 

 

 

Console speed:

Sets the baud speed for a terminal which might be

 

connected to the VisuaLink serial port.

Console parity:

Sets the parity and data length for a terminal which might

 

be connected to the VisuaLink serial port.

Note 1: To select an item use the up and down portion of the CAMERA CONTROL button.

Note 2: To change a setting use the left and right portion of the CAMERA CONTROL button to toggle through the item.

Note 3: Appendix A is a table detailing MLP to LSD speed setting relationship.

Press ENTER button to define after changing a setting.

Press the MENU and CANCEL button three (3) times to proceed back to the video image.

Page 5-12

NDA-24230 Issue 2.0