NDA-24296 CHAPTER 3

Page 217

Revision 1.0

PH-CK17

Phase Lock Oscillator

5. Exte rn al Inter face

When this ci rcuit ca rd is lo cate d in the T SW M, connect 3 4PH E XCL K CA- A to th e EXC LK0 /EXC LK 1

connectors o n t he backplane of the TSWM.

Figure 3-23 LT Connector Lead L ocation of PLO ( TSWM)

00 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23
Slot No.
TSWM
FRONT VIEW
PLO #1
PLO #0
26 1
FM 1
27 2
FM 0
28 3
SYN 1B
E
29 4
SYN 0B
E
30 5
DIU 3B
SYN 1A
31 6
DIU 2B
SYN 0A
32 7
DIU 1B
DIU 3A
33 8
DIU 0B
DIU 2A
34 9
DCS B
DIU 1A
35 10 DIU 0A
36 11 DCS A
37 12
38 13
EXCLK0
(Slot No.21)
EXCLK1
(Slot No.23)
TSWM
REAR VIEW
34PH EXCLK
CA-A
34PH EXCLK CA-A
34PH EXCLK CA-A LEAD ACCOMMODATION
Installation Cable
MDF
To Digital Interface and/or DCS

Mounting Module TSWM