NDA-24296 CHAPTER 2
Page 121
Revision 1.0
PH-SW10
Time Division Switch
Note: When MUX card mode (SW03-4 ON), only MUX and CFT functions are valid. M UX 1 is used for a con-

nection to T SW (Dont use MUX 2, 3). The LED of MUXACT, M0SY, CFT, and PMCA are valid, other LED

is not lit. In this mode, only SW03 is valid.

SWITCH
NAME SWITCH
NO SETTING STANDARD
SETTING MEANING
SW03
1ON 3-Party Conference Trunk (CFT) is valid.
OFF 3-Party Conference Trunk (CFT) is invalid.
2ON Setting of A-law in the CFT function block.
OFF ×Setting of µ-law in the CFT function block.
3OFF ×Fixed.
4
ON Only MUX function is valid (If this card is mounted in PIM
1/2/3). Note
OFF ×TSW/INT/PLO/MUX are v alid (When this card is mounted in
PIM 0).
SW04
1ON DIU 0 is used as the DTI cl ock supply route zero.
OFF DIU 0 is not used.
2ON DIU 1 is used as the DTI cl ock supply route one .
OFF DIU 1 is not used.
3ON DIU 2 is used as the DTI clock sup ply rout e two.
OFF DIU 2 is not used.
4ON DIU 3 is used as the DTI clock sup ply route three.
OFF DIU 3 is not used.
5ON ×1.5 M clock for DIU 0
OFF 2 M clock for DIU 0
6ON ×1.5 M clock for DIU 1
OFF 2 M clock for DIU 1
7ON ×1.5 M clock for DIU 2
OFF 2 M clock for DIU 2
8ON ×1.5 M clock for DIU 3
OFF 2 M clock for DIU 3