CHAPTER 3 NDA-24296
Page 286
Revision 1.0
PA-CS33
Attendant Interface
SW10
(TAS#0)
SW13
(TAS#1)
1
SW10 and SW13 designate the current limit resistance for TAS#0 and T AS#1 respectively.
2
3
4 This s witch designat es t he TAS signa ling sys tem in conjun ction wi th SW 11/12 a nd SW14/15.
SW11/
SW12
(TAS#0)
SW14/
SW15
(TAS#1)
SW11/12 and SW14/15 designate the TAS#0 and TAS#1 signaling system (in conjunction with SW10-4
(TAS#0)/SW13-4 (TAS#1).
SWITCH
NAME SWITCH
NO SETTING S TANDARD
SETTING MEANING
SW10-3/
SW13-3 SW10-2/
SW13-2 SW10-1/
SW13-1 STANDARD
SETTING RESISTANCE
ON ON ON 0
ON ON OFF 220
ON OFF ON 398
ON OFF OFF 618
OFF ON ON 800
OFF ON OFF 1020
OFF OFF ON 1198
OFF OFF OFF ×1418
SW12/
SW15 SW11/
SW14 SW10-4/
SW13-4 STANDARD
SETTING
SIGNAL WHEN SEIZED
TAS 0A/
TAS 1A TAS 0B/
TAS 1B
ON ON ON CR G
OFF ON ON -48V G
OFF OFF OFF ×LOOP LOOP
OFF OFF ON G G