CHAPTER 3 NDA-24296
Page 204
Revision 1.0
PH-CK16-A
Phase Lock Oscillato r

Cable Connection Diagram

Provide the following wiring at the MDF. The connection diagram in Figure 3-15 shows an example of a

system with the PLO cards in dual configuration.

Figu re 3-15 Cable Connection Dia gra m (ISWM) fo r Acceptin g S ync hr on ization Clocks f ro m an Extern al
High-Stability Oscillator
MDF
ISW/CMG
External
High-Stability
Oscillator #1
CLK
External
High-Stability
Oscillator #0
CLK
PCM Cable(IP)
PCM Cable(IP)
DCSA
DCSB
LT Connector Cable
EXCLK1 DCSB
DCSA
LT Connector Cable
EXCLK0
EXCLK1
PLO#1
EXCLK0
PLO#0
BASEU
ISWM
maximum 400 meters (1320 feet) (24 AWG)