NDA-24296 CHAPTER 2
Page 145
Revision 1.0
PU-SW01
Highway Switch
5. Switch Settings
Switch settings on this circuit card are shown in the table below.
6. E x te rn al Interface
No cable connections are required.
7. Switch Setting Sheet
CKAL3 Green Lights when the clock signal is sent normally from #03 circuit of TSW in ISWM.
Off Goes off when the clock failure occurs on #03 circuit of TSW in ISWM.
CKAL2 Green Lights when the clock/Frame Head signals are sent from #02 circuit of TSW in ISWM.
Off Goes off when the clock/Frame Head signals are not sent from #02 circuit of TSW in ISWM.
CKAL1 Green Lights when the clock/Frame Head signals are sent from #01 circuit of TSW in ISWM.
Off Goes off when the clock/Frame Head signals are not sent from #01 circuit of TSW in ISWM.
CKAL0 Green Lights when the clock/Frame Head signals are sent from #00 circuit of TSW in ISWM.
Off Goes off when the clock/Frame Head signals are not sent from #00 circuit of TSW in ISWM.
SWITCH
NAME SETTING STANDARD
SETTING MEANING
MB UP Circuit card Make-busy.
DOWN ×Circuit card Make-busy cancel.
SWITCH NAME SWITCH SHAPE REMARKS
MB
L AMP N AME COL OR STATE
ON