CHAPTER 3 NDA-24296
Page 356
Revision 1.0
PA-16ELCJ
Electric Line Current
4. Lamp Indications
Lamp indications for this circuit card are shown in the table below.
Note: When the PALM lamp lights red, observe the following instructions.
i) Identify the location where any in-house wires have a short circuit in all lines which belong to the
PA-16ELCJ card whose PALM is on.
ii) Repair the short-circuited wires of the associated Dterm.
iii) Disconnect the Dterm from the rosette, then leave it disconnected for at least one minute.
iv) Connect the Dterm again.
LAMP NAME COLOR STATE
OPE Green Remains lit while on-line operations are normal.
OFF Of f when on-l ine opera tions are abnormal .
PALM Red Lights red when power supply circuit(s) is abnormal. Note
OFF Of f when all t he power sup ply circuits are normal .
BL0
BL15
Green Lights when the corresponding circuit is busy.
Flash Flashes when the corresponding circuit is in Make-busy state or station data has not been
assigned.
OFF Off when the corresponding circuit is idle.
-