NDA-24296 CHAPTER 3
Page 309
Revision 1.0
PA-16LCBE
Line Circuit
SWITCH
NAME SWITCH
NO. SETTING STANDARD
SETTING MEANING
SW1
1ON Polarity Reversal as Disconnec t Signal
OFF ×Momentary Open as Disconnect Signal
2OFF ×Fixed
3
4
SW1-3 SW1-4 INTERRUPTED RINGER PATTERN
OFF
(standard) OFF
(standard)
OFF ON
ON OFF
ON ON
0.4/0.2/0.4-ON/OFF/ON
Inco m in g c al l fro m C. O. line/s ta tion
0.4 0.4
0.2
2.0
Rering
0.4 0.8
0.2
4.00.4
0.2
0.2/0.2/0.2/0.2-ON/OFF/ON/OFF/ON
Inc om in g c a ll f r om C. O. line /stat ion
0.2 0.2
0.2
2.0
Rering
0.2 0.2
0.2
4.00.4
0.2
0.2
0.2
0.2 0.2
0.20.2
0.35/0.3/0.35-ON/OFF/ON
Incoming cal l from C. O. line/station
0.35 0.35
0.3
2.0
Rering
0.35 0.7
0.3
4.00.35
0.3
0.2/0.4/0.2-ON/OFF/ON
Incoming call from C. O. line/station
0.2 0.2
0.4
2.2
Rering
0.2 0.2
0.4
4.2
0.2 0.4
0.2 0.2