NDA-24296 CHAPTER 3
Page 469
Revision 1.0
PA-24CCTA
Comm on Channel Trunk
SWITCH
NAME SWITCH
NO. SETTING STANDARD
SETTING MEANING
SW02/
MODE Transmission Guard Timer Setting (sec.)
0×4 (sec.)
15 (sec.)
26 (sec.)
37 (sec.)
48 (sec.)
59 (sec.)
6 10 (sec.)
7 11 (sec.)
8 12 (sec.)
9 13 (sec.)
A 14 (sec.)
B 15 (sec.)
C 16 (sec.)
D 17 (sec.)
E 18 (sec.)
F 19 (sec.)
SW10/4D 1ON Logic of Signal Channel A (Receive): Negative
OFF ×Logic of Signal Channel A (Receive): Positive
2ON Logic of Signal Channel A (Send): Negative
OFF ×Logic of Signal Channel A (Send): Positive
3ON RMT Alarm Sending: Not to be sent out
OFF RMT Alarm Sending: To be sent out
4ON Simultaneous Seizure Supervision: Not to be controlled
OFF Simultaneous Seizure Supervision: To be controlled
5ON Data Link Control: MOS
OFF Data Link Control: BOS
6ON Multif r ame Selection : 12-Multiframe
OFF Mult if r ame Selection : 24-Mul tifr am e
7ON Coding Type: A MI (Alte rnate Mar k Inve rsion)
OF F C o ding Type : B8Z S (B ipolar with 8 Ze ros Substit utio n)
8ON Fixe d to ON. Whe n t his sw itch is set to ON, Alarm Proc ess ing
is selected for North America specification.
OFF