CHAPTER 3 NDA-24296
Page 280
Revision 1.0
PA-CS08-B
Hotel Attendant Interface
Note: When PB signal is sent from the Hotel ATT, set the SW 12-1~ 4 ON, and assign AHSY command, INDEX
114, b7 = I.
SWITCH SWITCH
NO. SETTING STANDARD
SETTING MEANING
SW11 1ON
OFF ×Fixed
2ON
OFF ×Fixed
3ON
OFF ×Fixed
4ON
OFF ×Fixed
SW12 1ON ×
Fixed (all ON)
OFF
2ON ×
OFF
3ON ×
OFF
4ON ×
OFF
SW9 0ON No. 0 System is in make-busy request.
OFF ×Normal setting
1ON No. 1 System is in make-busy request.
OFF ×Normal setting
2OFF ×Not used
3OFF ×Not used