NDA-24296 CHAPTER 3
Page 347
Revision 1.0
PA-16LCBY
Line Circuit
SWITCH No. FUNCTION SWITCH SETTING MEANING
SW11
(BNW8-15) Balancing Network
Designation
Each element on this
switch corresponds
to circuit #8-#15.
[the sam e as pre vious page]
SW14 1 OFF Fixed to OFF
2ONFixed to ON
3 OFF Fi xed to OFF
4 OFF Fi xed to OFF
SW15
1
North America
Brazil
China
Other Country
OFF Fixed to OFF
PAD (Australia Only)
ON NEAX 2400 PAD
PA D ON/OFF = 9dB/0dB
OFF ICS-PBX PAD
PA D ON/OFF = 9dB/6dB
2ON Stutter Dial Tone Available
OFF Stutter Dial Tone not Available
3 OFF Fi xed to OFF
4 OFF Fi xed to OFF
12345678
ON
OFF
1234
ON
OFF
1234
ON
OFF