NDA-24296 CHAPTER 3
Page 373
Revision 1.0
PA-FCHA
Fusion Call Con trol Handler

5. Switch setting

Standard settings for switches on this circuit card are shown in the table below.
Note: The following operations are required prior to extracting the card.

(1.) Turn on the MNT3 switch.

(2. ) Flip the MB switch.

When the D/I DTI (1.5M) is connected with the card front cable.

Note: T203 t imer designates the maximum idl e t ime whic h does no t tr ans mit any dat a frame s. As a basic rule, the

shorter T203 timer value, t he earlier link failure detection will be obtained.

SWITCH
NAME SWITCH
NO. SETTING STANDAR D
SETTING DESCRIPTION
MB
Note
UP Circuit card Make-busy.
DOWN ×Circuit card Make-busy cancel.
MNT
0OFF ×Not used.
1OFF ×Not used.
2OFF ×Not used.
3
Note
ON Make-busy-request.
OFF ×Cancel the Make-busy-request.
SWITCH
NAME SETTING STANDARD
SETTING DESCRIPTION
MODE
0 - 7 Not used.
8×Standard setting.
(When the DTI is connected with the card front cable.)
9Fusion link test mode.
(When the DTI is connected with the card front cable.)
A - F Not used.
SWITCH
NAME SWITCH
NO. SETTING STANDAR D
SETTING DESCRIPTION
SW10
1
Note
ON T2 0 3 ti mer val u e is vari ab l e.
OFF ×T203 timer value is fixed at 10 seconds.
2~8 OFF ×Not used.