NDA-24296 CHAPTER 3
Page 613
Revision 1.0
PA - 24 D TR ( D LI)
Digital Line Interface
Note: This PAD va lue table is PAD pa ttern 1. I f other PAD pa ttern is req uired , assign PAD pa ttern by elemen ts
4~6 of SW12/58. The elements become valid when assigning ASYD SYS1 INDEX4 bit5=1. When ASYD
SYS1 INDEX4 bit5=0, PAD value is 0dB.
SWITCH
NAME SWITCH
NO. SETTING STANDARD
SETTING MEANING
SW13/6C 1O N Main Signal All 1 Supervision: Valid
OFF ×Ma in Signal All 1 Supervision: Invalid
2ON ×Ringer Control: Continuous
OFF Ringer Control: Int ermittent
3ON Sending PAD Value Selection (PAD Pattern1) Note
OFF ×
4ON
OFF ×
5ON ×
OFF
6ON Receiving PAD Value Selection (PAD Pattern1) Note
OFF ×
7ON
OFF ×
8ON
OFF ×
SW13/ 6C- 3 SW13/ 6C-4 SW13/ 6C- 5 PAD Value
OFF OFF OFF 0 dB
OFF OFF ON 2 dB
OFF ON OFF 4 dB
OFF ON ON 6 dB
ON OFF OFF 8 dB
ON OFF ON 0 dB
ON ON OFF 0 dB
ON ON ON 0 dB
SW13/ 6C- 6 SW13/ 6C-7 SW13/ 6C- 8 PAD Value
OFF OFF OFF 0 dB
OFF OFF ON 2 dB
OFF ON OFF 4 dB
OFF ON ON 6 dB
ON OFF OFF 8 dB
ON OFF ON 0 dB
ON ON OFF 0 dB
ON ON ON 0 dB