NDA-24296 CHAPTER 3
Page 329
Revision 1.0
PA-16LCBJ-B
Line Circuit
Note: Compromise Impedance (EIA/TIA- 464A) and 600 are composed as follows.
SWITCH NAME SETTING
SW-10
(BNW0 - 7) Balancing Network
Designation
Each element
corresponds to
circuits 0 - 7.
BNW: Compromise Impedance
(EIA/TIA-464A)
for long distance
BNW: 600
for short distance
SW-11
(BNW8 - 15) Balancing Network
Designation
Each element
corresponds to
circuits 8 - 15.
BNW: Compromise Impedance
(EIA/TIA-464A)
for long distance
BNW: 600
for short distance
ON OFF
123456 7 8
ON
OFF

ON
OFF

12 3 4 5 6 7 8
ON
OFF

ON
OFF

compromise impedance (EIA/TIA-464A)
3501000
0.21 µ
600