PA-8TLTR
Tie Line Trunk
Note: For the setting range of Programmable PAD Values, see the Setting Range of Programmable PAD

Values shown for S W1.

SWITCH SWITCH
NO. SETTING STANDARD
SETTING MEANING
SW3
(SW25) 1ON Progra mmabl e PAD P2 Value 0.5 dB
P2 Values is total
of PAD Values
Note
(Valid when 4W
E&M system)
(Ex)
SW3-1: OFF
SW3-2: ON
SW3-3: OFF
SW3-4: OFF
in this case P2
value i s 1 dB.
P3 Values is total
of PAD Values
Note
(Valid when 4W
E&M system)
(Ex)
SW3-5: OFF
SW3-6: ON
SW3-7: OFF
SW3-8: OFF
in this case P3
value i s 1 dB.
OFF Progra mmabl e PAD P2 Value 0 dB
2ON Programmable PAD P2 Value 1 dB
OFF Progra mmabl e PAD P2 Value 0 dB
3ON Programmable PAD P2 Value 2 dB
OFF Progra mmabl e PAD P2 Value 0 dB
4ON Programmable PAD P2 Value 4 dB
OFF Progra mmabl e PAD P2 Value 0 dB
5ON Programmable PAD P3 Value 0. 5 dB
OFF Progra mmabl e PAD P3 Value 0 dB
6ON Programmable PAD P3 Value 1 dB
OFF Progra mmabl e PAD P3 Value 0 dB
7ON Programmable PAD P3 Value 2 dB
OFF Progra mmabl e PAD P3 Value 0 dB
8ON Programmable PAD P3 Value 4 dB
OFF Progra mmabl e PAD P3 Value 0 dB