CHAPTER 2 NDA-24296
Page 108
Revision 1.0
PH-PC45
Emergenc y Alarm Controller
SWITCH
NAME SWITCH
NO SETTING STANDARD
SETTING MEANING
SW62
1ON Power Shut Down (PSDN) function
(used in Australia only)
OFF ×
2ON
OFF ×
3ON
OFF ×
4ON
OFF ×
SW65
1ON ×Output the CPU-A CT Signal to the another EMA (when this
circuit card is used in the one frame stack configuration).
OFF CPU-ACT Signal does not output.
2ON Not used.
OFF ×Not used.
3ON Dual CPU configuration.
OFF Single CPU configur ation.
4ON ×PZ-DK223 (or PZ-DK173) is used for the DSPP on the
TOPU.
OFF PZ-DK179 is used for the DSPP on the TOPU.
SW70
1ON External mu sic on hold source (FM lead) is used.
OFF Internal music on hold source IC is used.
2ON Output the alarm information for the external ind ic ator
(used in Australia only).
OFF ×Alarm information does not output.
SW73
1ON ×Power Failure Transfer (PFT) control is valid.
OFF P FT cont r ol is invalid.
2ON ×µ-law PCM CODEC is applied for the music.
OFF A-law PCM CODEC is applied for the music.
SW62 ON OFF
SW62 -1 I M G# 0 valid IMG 0# invalid
SW62 -2 I M G# 1 valid IMG 1# invalid
SW62 -3 I M G# 2 valid IMG 2# invalid
SW62 -4 I M G# 3 valid IMG 3# invalid