NDA-24296 CHAPTER 3
Page 271
Revision 1.0
PA-CS08
Hotel Attendant Interface
5. Switch Settings

Stand ard s et t ing s for various s w itche s o n t h i s circ uit card ar e shown in the table b elow.

SWITCH SWITCH
NO. SETTING STANDARD
SETTING MEANING
MB
UP Circuit card Make-busy.
DOWN Cir cuit ca r d Make-busy ca n c el.
SW02 (TAS0)
SW03 (TAS1)
1
2
3
4
SW04
1ON ×Fixed
2OFF ×Fixed
3ON ×Fixed
4OFF ×Fixed
SW07 (TAS0)
SW08 (TAS1)
1
2
3
4
SETTING OF TAS SIGNALLING SYSTEM
SWITCH TAS (A WIRE) TAS (B WIRE)
1-48VG
2CRG
3GG
4 LOOP LOOP
SETT ING OF TAS CURRENT LIMIT RESISTANCE
SW7-1/
SW8-1 SW7-2/
SW8-2 SW7-3/
SW8-3 SW7-4/
SW8-4 RESISTANCE
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
ON
OFF
OFF
ON
ON
OFF
OFF
ON
ON
ON
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
0
200
390
590
820
1020
1210
1410