5-44 Installing and Using Utilities
PCI Module(ID:n/m)
PCI Module contains the following information:
The MTBF information is displayed only when the [<MTBF Info>] button is pressed.
Item | Description |
Status | Status of the PCI module |
㩷
MTBF Information contains the following information:
Item | Description |
Type | Monitoring state of MTBF. |
| Use Threshold: MTBF is calculated at a fault occurrence. The device is stopped |
| when the calculated value is lower than the threshold. |
| Never Restart: Always stops the device at a fault occurrence. |
| Always Restart: Always restarts the device at a fault occurrence. |
Threshold | Threshold of MTBF. |
Current | Current MTBF value. |
Faults | Number of faults |
Time of last fault | Time of the last fault. |
| When there is none, |
Diagnostics Information contains the following information:
Item | Description |
Time of last run | Time and date of the last diagnostics execution |
Message | Message from the diagnostics result |
Test No. | Test number from the diagnostics result |
㩷
The following buttons are displayed for PCI Module:
Item | Description |
MTBF Info | Displays MTBF information |
Clear | Clears the MTBF information of the PCI module |
Up | Starts the PCI module. |
| The CPU module of the same module must be stopped when starting the PCI |
| module. When the CPU module of the same module is running, stop the CPU |
| module and then start it after starting the PCI module. |
Down | Stops the PCI module. |
| Depending on a module state, a screen will go off temporarily. Also, USB |
| devices such as a keyboard and a mouse may not be available for a few |
| minutes. However, a system continues operating. |
| You cannot stop the module when the FT status LED is not illuminating green |
| (when the server is not duplicated). |
Diagnose | Executes diagnostics of the CPU module on the same module as the PCI |
| module. To perform diagnostics, both CPU and PCI modules on the module |
| needs to be stopped. |
*(1) The execution of each button may take a few minutes. Wait for a while to update the display and check the module status.
(2)These operations cannot be performed while collecting dump or updating firmware. Wait until such processing is finished to perform the operations in the table.