Troubleshooting 7-15

 

 

 

 

 

 

Message

Meaning

Action

 

 

 

 

 

 

 

The driver failed to switch

The driver was unsuccessful to

There may be problem in

 

 

Primary/Secondary state of the

change the primary/secondary

the hardware environment.

 

 

IO module.

state of the IO module.

Contact your sales agent.

 

 

 

 

 

 

 

The driver started to bind the

The driver started bindng the

The server is operating

 

 

Module.

CPU/IO module.

normally.

 

 

The driver finished successfully

The driver successfully bounded

 

 

 

to bind the Module.

the module.

 

 

 

 

 

 

 

 

The driver failed to bind the

The driver was unsuccessful to

There may be problem in

 

 

Module.

bind the module.

the hardware environment.

 

 

 

 

Contact your sales agent.

 

 

 

 

 

 

 

The driver accepted to remove

The driver received an instruction

The server is operating

 

 

the Module.

to disconnect the module.

normally.

 

 

 

 

 

 

 

The driver started to remove

The driver started disconnecting

 

 

 

the Module.

the module.

 

 

 

The driver finished successfully

The driver successfully

 

 

 

to remove the Module.

disconnected the module.

 

 

 

 

 

 

 

 

The driver failed to remove the

The driver was unsuccessful to

There may be problem in

 

 

Module.

disconnect the module.

the hardware environment.

 

 

 

 

Contact your sales agent.

 

 

 

 

 

 

 

The driver accepted to update

The driver received an instruction

The server is operating

 

 

the BIOS.

to update BIOS.

normally.

 

 

 

 

 

 

 

The driver started to update the

The driver started updating

 

 

 

BIOS.

BIOS.

 

 

 

 

 

 

 

 

The driver finished successfully

The driver successfully updated

 

 

 

to update the BIOS.

BIOS.

 

 

 

The driver failed to update the

The driver was unsuccessful to

There may be problem in

 

 

BIOS.

update BIOS.

the hardware environment.

 

 

 

 

Contact your sales agent.

 

 

The error occurred on the

There was a South Bridge error.

 

 

 

 

South Bridge.

 

 

 

 

 

 

 

 

 

FT nonfatal error occurrred.

NEC GeminiEngine HA System

If the message is recorded

 

 

 

Controller detected an error.

frequently, there may be

 

 

 

 

problem in the hardware

 

 

The error occurred on the CPU

There was a CPU module error.

 

environment. Contact your

 

 

module.

 

 

 

 

sales agent.

 

 

 

 

 

 

 

 

 

 

 

The error occurred on the PCI

There was a PCI Express error.

There may be problem in

 

 

Express.

 

the hardware environment.

 

 

 

 

Contact your sales agent.

 

 

The driver detected that the

A module error was detected.

 

 

 

 

Module was not working.

 

 

 

 

 

 

 

 

 

DMA error occurred.

There was a DMA error.

There may be problem in

 

 

 

 

the hardware environment.

 

 

Legacy device error occurred.

There was a legacy device error.

 

Contact your sales agent.

 

 

 

 

 

 

Surprise remove occurred.

Supprise removal occurred.

 

 

 

 

 

 

 

Page 287
Image 287
NEC N8800-090F, EXP320A, EXP320B, N8800-091F manual Bios

N8800-091F, EXP320B, EXP320A, N8800-090F specifications

The NEC N8800-090F, EXP320A, EXP320B, and N8800-091F are advanced computing solutions designed for demanding enterprise environments. These models are part of NEC's high-performance computing portfolio, tailored for data-intensive applications and virtualization.

The N8800-090F is a robust server featuring powerful multi-core processors, providing exceptional performance for complex calculations and heavy workloads. This server supports a variety of memory configurations, enabling scalability and flexibility to meet the evolving needs of businesses. Its architecture is designed to facilitate high availability, ensuring that critical applications remain operational even in the event of hardware failures.

The EXP320A and EXP320B are expansion units that complement the N8800 series by providing additional storage and I/O capacity. They are ideal for organizations that require massive data storage solutions. These expansion units support different types of storage media, including high-speed SSDs and high-capacity HDDs. This allows for a customizable approach to data management, catering to various performance and capacity requirements.

One of the standout features across these models is their support for advanced virtualization technologies. The systems are equipped with features that enable efficient resource management, allowing multiple virtual instances to run on a single physical server without significant performance degradation. This is crucial for businesses looking to optimize their IT resources and improve operational efficiency.

Furthermore, NEC has integrated advanced security features into these servers to protect sensitive data and ensure compliance with industry regulations. This includes hardware-based security mechanisms, secure boot processes, and comprehensive management tools that provide organizations with enhanced control over their server environments.

Overall, the NEC N8800-090F, EXP320A, EXP320B, and N8800-091F present a compelling choice for enterprises looking for reliable, scalable, and high-performance computing solutions. With their cutting-edge technologies and robust design, these models aim to support the growth and adaptability of modern IT infrastructures while delivering exceptional performance for a wide range of applications.