NEC N8800-091F, EXP320A, EXP320B, N8800-090F manual RAID Configuration When Disks are Added, = Scsi

Models: N8800-091F EXP320B EXP320A N8800-090F

1 358
Download 358 pages 35.98 Kb
Page 322
Image 322

8-10 System Upgrade

RAID CONFIGURATION WHEN DISKS ARE ADDED

Use ftdiskadm to configure RAID when disks are added.

From “SCSI” – “Bring Up,” specify slot numbers and add the disks to the system. Then, from “RAID”

– “New Disks,” configure RAID.

Following is an example of adding disks to Slot 2 and Slot 5 using ftdiskadm:

(Example of adding disks to the system)

#ftdiskadm Command Action

1

=> RAID

2

=> SCSI

9

Quit

Command:2

Command Action

1 Bring Down(System Disk)

2 Bring Up(System Disk)

3 Status(System Disks)

9 <= Return

Command:2

 

[Bring Up(System Disk)]

<<<Add the disk in Slot2>>>

Which scsi SLOT?[0-5]:2

Command Action

 

1

Bring Down(System Disk)

 

2

Bring Up(System Disk)

 

3

Status(System Disks)

 

9

<= Return

 

Command:2

 

[Bring Up(System Disk)]

<<<Add the disk in Slot5>>>

Which scsi SLOT?[0-5]:5

Command Action

 

1

Bring Down(System Disk)

 

2

Bring Up(System Disk)

 

3

Status(System Disks)

 

9

<= Return

 

Command:3

<<<Confirm that the disks are added to the system>>>

[SCSI DISK STATUS]

 

-- SYSTEM --

path

slot name use serial

0hada 2 V3W1N8RA0050B5CL0399 h1c0t0l0ACT h7c0t0l0HOT

1-

2hadc 0 V3W45ZVA0050B5CL0707 h1c0t2l0ACT h7c0t2l0HOT

3hadb 2 V3W1RK5A0050B5CK040D h2c0t3l0ACT h8c0t3l0HOT

4-

5

hadd 0

V3W1D30A0050B6120DED h2c0t5l0ACT h8c0t5l0HOT

Page 322
Image 322
NEC N8800-091F, EXP320A, EXP320B, N8800-090F manual RAID Configuration When Disks are Added, = Scsi