NEC N8800-091F, EXP320A, EXP320B, N8800-090F manual Check

Models: N8800-091F EXP320B EXP320A N8800-090F

1 358
Download 358 pages 35.98 Kb
Page 246
Image 246

5-62 Installing and Using Utilities

[Down] of the module you want to stop.

7.Click [Diagnostics] on the [Maintenance] screen of the other PCI module stopped.

8.Start the other stopped module.

Starting the module causes the firmware to be updated automatically. However, if the [Enable automatic firmware update] property is disabled, the module is started but the firmware will not be updated. In such a case, perform the following operations before starting the module:

(1)Click the [Firmware Update] button in the [Update] screen for the target component.

(2)In the [Firmware Update] dialog box, select [Copy online BIOS image to Offline] as a method for updating, and click [Execute].

IMPORTANT:

A message prompting you to reconstruct the tree of Data Viewer you are updating may appear. In such a case, click [Yes].

CHECK:

When stopping IO module, check that the status of Ethernet is “Duplex” on NEC ESMPRO Manager. Do not stop the IO module especially when LAN is connected only to the IO module on that side.