NEC N8800-090F, EXP320A, EXP320B, N8800-091F manual Procedure in NEC Esmpro Manager „ Start, „ Stop

Models: N8800-091F EXP320B EXP320A N8800-090F

1 358
Download 358 pages 35.98 Kb
Page 235
Image 235

Installing and Using Utilities 5-51

but the link cable of a teamed LAN is connected to only one side of the modules or when a storage device connected by FC is connected to only one side of the modules.

Procedure in NEC ESMPRO Manager

„Start

1.Select the target component in the [ft] tree.

2.Check the current state with the "State" display on the target component screen.

3.Click the [Bring Up] button in the [Maintenance] screen for the target component. A certain time is required for the start.

The start result can be confirmed by "State" on the target component screen. The result of the start operation is reported by the server as an alert.

CHECK:

When starting a stopped IO module, diagnostics of the CPU/IO modules are automatically performed. The IO module is started after the diagnostics.

„Stop

Perform the procedure below before replacing a component.

1.Select the target component in the [ft] tree.

2.Check the current state with the "State" display on the target component screen.

3.Click the [Bring Down] button in the [Maintenance] screen for the target component. A certain time is required for the stop.

The stop result can be confirmed by "State" on the target component screen. The result of the stop operation is reported by the server as an alert.

CHECK:

When stopping IO module, check that the status of Ethernet is “Duplex” on NEC ESMPRO Manager. Do not stop the IO module especially when LAN is connected only to the IO module on that side.

Page 235
Image 235
NEC N8800-090F, EXP320A, EXP320B, N8800-091F manual Procedure in NEC Esmpro Manager „ Start, „ Stop