| Troubleshooting |
|
|
|
|
|
| Cause | Action |
| 9058 - 905F | This CPU/IO module detected | CPU configuration may be |
|
| the mismatch of CPUID | different between the CPU/IO |
|
| between the CPU/IO | modules. |
|
| modules. | Replace the CPU. |
|
|
| If this does not help, replace the |
|
|
| CPU/IO module. |
| 9062 - 9063 | CPU/IO module or ft Remote | If turning AC power off and on |
|
| Management Card (option) is | does not help, replace the |
|
| faulty. | CPU/IO module or ft Remote |
|
|
| Management Card (option). |
| 9065 | One or both the CPU/IO | There are some error messages |
|
| modules have a problem. | in addition to this error code. |
|
|
| Check the other error message. |
| 9071 - 9072 | Replace the | |
|
| out. | If this does not help, replace the |
|
|
| CPU/IO module. |
| 9080 - 908F | This CPU/IO module failed to | When the system is running in |
| 9080 - 9085 | get the information from | the duplex mode, it is no |
| 9087 - 908F | another CPU/IO module. | problem. |
|
|
| If the system cannot be running |
|
|
| in the duplex mode due to |
|
|
| continuous this error, replace the |
|
|
| CPU/IO module. |
|
|
| If this does not help, replace |
|
|
| another CPU/IO module or |
|
|
| center plane. |
| 9086 | The CPU/IO modules were | The GA driver may not support |
|
| unsuccessful to share | the server. Confirm that the driver |
|
| information. | is an appropriate one and restart |
|
|
| the server. |
|
|
| If this does not help, replace the |
|
|
| CPU/IO module or center plane. |
| 9026 | The chip set revisions are | The model of the CPU/IO |
|
| mismatched. | modules mounted to the CPU |
|
|
| modules is different. Replace the |
|
|
| CPU/IO modules with those of |
|
|
| the same model. |