NEC EXP320A, EXP320B, N8800-091F manual Disconnecting a disk from the system and adding a new disk

Models: N8800-091F EXP320B EXP320A N8800-090F

1 358
Download 358 pages 35.98 Kb
Page 88
Image 88

3-6 Linux Setup and Operation

4 Remove Full Disks

5 Status(Raid)

6 Status(All Disks)

9 <= Return

Command:2

[Remove Half Disk] Which scsi SLOT?[0-5]:3

mdadm: set /dev/hadb2 faulty in /dev/md1

mdadm: hot removed /dev/hadb2

mdadm: set /dev/hadb3 faulty in /dev/md2

mdadm: hot removed /dev/hadb3

mdadm: set /dev/hadb1 faulty in /dev/md0

mdadm: hot removed /dev/hadb1

Command Action

1 New Disks

2 Remove Half Disk

3 Repair Disk

4 Remove Full Disks

5 Status(Raid)

6 Status(All Disks)

9 <= Return

Command:5

<<<Confirm that the disk is disconnected from RAID>>>

[Status(Raid)]

Status

Member

Name

Partition

--------------------------------------------------

md1

/

simplex

(0)hada2

md2

/boot

simplex

(0)hada3

md0

simplex

(0)hada1

Command Action

 

 

1

New Disks

 

 

2

Remove Half Disk

 

3

Repair Disk

 

 

4

Remove Full Disks

 

5

Status(Raid)

 

6

Status(All Disks)

 

9

<= Return

 

 

Command:9

(Disconnecting a disk from the system and adding a new disk)

Command Action

1 => RAID

2 => SCSI

9Quit

Command:2

Command Action

Page 88
Image 88