Troubleshooting 7-9

 

 

 

 

 

On-screen error message

Cause

Action

 

9039 Not keep last boot

Unintended operations such

Reconfigure the boot option by

 

order

as incorrect DC off are

using the BIOS setup. If

 

 

performed.

reconfiguring the boot option

 

 

 

does not help, replace the

 

 

 

CPU/IO module.

 

9070 The error occurred

The sensor of water-cooling

Replace the water-cooling kit. If

 

during water-cooling

kit is faulty.

turning on/off AC does not help,

 

unit sensor reading

 

replace CPU/IO module or ft

 

 

 

Remote Management Card.

 

NOTICE System is force

Abnormality of one or both

View other error information and

 

boot with POST

sides of modules is detected.

the error information of standby

 

error

 

CPU/IO module.

 

9000

A serious error occurred

There are some error messages

 

 

during a POST.

in addition to this error code.

 

 

 

Check the other error message.

 

 

 

 

9007

Forced power off occurred by

Pull out another CPU/IO module

 

 

another CPU/IO module has

and install it.

 

 

a problem.

If this does not help, replace the

 

 

 

CPU/IO module.

 

9008

Forced power off occurred by

Pull out another CPU/IO module

 

 

another CPU/IO module has

and install it.

 

 

a problem.

If this does not help, replace the

 

 

 

CPU/IO module.

 

9010 - 9015

Can not boot from target Disk.

Check the target disk.

 

 

 

In addition, replace it if required.

 

 

 

If this does not help, replace the

 

 

 

CPU/IO module.

 

9020

CPU is faulty.

Replace the CPU.

 

 

 

If this does not help, replace the

 

 

 

CPU/IO module.

 

9022 - 9023

Initialization of the cross-link

When the system is running in

 

 

between the CPU/IO modules

the duplex mode, it is no

 

 

and access are faulty.

problem.

 

 

 

If the system cannot be running

 

 

 

in the duplex mode due to

 

 

 

continuous this error, replace the

 

 

 

CPU/IO module.

 

 

 

If this does not help, replace

 

 

 

another CPU/IO module or

 

 

 

center plane.

 

9024

Disconnect the cross-link

When the system is running in

 

 

between the CPU/IO

the duplex mode, it is no

 

 

modules.

problem.

 

 

 

If the system cannot be running

 

 

 

in the duplex mode due to

 

 

 

continuous this error, replace the

 

 

 

CPU/IO module.

 

 

 

If this does not help, replace

 

 

 

another CPU/IO module or

 

 

 

center plane.

Page 281