Parallel Port Addresses

Starting I/O Address

Port

378

LPT1

278

LPT1

3BC

LPT1

378

LPT2

278

LPT2

3BC

LPT2

 

 

Parallel interface signals are output through the system board’s 25-pin, D-subconnector. The connector is located at the back of the system unit.

Serial Interface

The system has two 16C550 UART compatible serial ports (COM1 and COM2) integrated on the I/O controller. The serial ports support the standard RS-232C interface. The buffered high- speed serial ports support transfer rates up to 115.2 KB. The ports allow the installation of high- speed serial devices for faster data transfer rates.

Sets of I/O addresses for the channels are given in the following table (see Section 2, “System Configuration,” for interrupt levels). Soft-selectable base addresses are 3F8h, 2F8h, 3E8h, and 2E8h.

Serial Port 1 and Serial Port 2 I/O Addresses

Starting I/O Address

Port

3F8

COM1

2F8

COM2

3E8

COM3

2E8

COM4

3F8

COM1

2F8

COM2

3E8

COM3

2E8

COM4

 

 

See Section 2, “System Configuration,” for information on resetting the port through the BIOS Setup Utility. See Section 9, “Specifications,” for the serial interface specifications.

Serial interface signals are output through the system board’s 9-pin, D-subconnector. The connector is located at the back of the system unit.

System Board 4-11