iR1200 Modem

Symptom

Troubleshooting Tips

 

modem.

 

The cable is connected to the correct

 

port.

 

The correct port is specified in your

 

communication software.

 

The modem is set to the same baud

 

rate specified in the communication

 

software.

 

 

The NO CARRIER

Make sure that the S7 register contains a

message displays

value greater than or equal to 60 by issuing

when the modem

an AT&V command or by explicitly

attempts data calls.

setting ATS7=’x’ (where x is, enter any

 

number between 1 and 255).

 

 

Modem does not auto-

Make sure that the S0 register contains a

answer incoming data

value other than 0 (zero) by issuing the

calls (not default

AT&V command. You can also explicitly

operation).

set ATS0=x from the software’s command

 

mode (where x is any number between 1

 

and 255).

 

 

Received data is

Make sure that the flow control is set to

unrecognizable.

RTS/CTS (hardware flow control is

 

enabled) in the communication software

 

and is set to &K3.

 

 

Data is being

Make sure that the flow control is set to

intermittently lost.

RTS/CTS (hardware flow control is

 

enabled) in the communication software

 

and is set to &K3.

 

 

Modem seems to

Check the signal strength icon to be sure

respond slower than

the signal is not weak.

usual.

 

 

 

92

nextel.com

Page 102
Image 102
Nextel comm IR1200 manual Modem