S-Registers

 

 

 

 

 

Register #

Function

 

 

 

Valid value ranges from 0 (zero) to 255. 0 (zero) is

 

 

 

the default value.

 

 

 

 

 

 

2

Escape (ESC) Code Character. Specifies the ASCII

 

 

 

character to be used to escape from either data or

 

 

 

online mode to command mode.

 

 

 

Valid value ranges from 0 (zero) to 127. 43 or the

 

 

 

ASCII plus (+) key is the default value.

 

 

 

 

 

 

3

Command Line Terminating Character. Specifies

 

 

 

the ASCII character to be used to terminate a

 

 

 

command line without carrying out any command

 

 

 

that might be issued.

 

 

 

Valid value ranges from 0 (zero) to 127. 13 (which

 

 

 

represents the ENTER (PC Compatible) or

 

 

 

RETURN (Macintosh) key) is the default value.

 

 

 

 

 

 

4

Response Format Character.

 

 

 

Valid value ranges from 0 (zero) to 127. 10 is the

 

 

 

default value.

 

 

 

 

 

 

5

Command Line Editing Character.

 

 

 

Valid value ranges from 0 (zero) to 127. 8

 

 

 

(representing the Backspace key) is the default

 

 

 

value.

 

 

 

 

 

 

6

Pause Before Blind Dialing.

 

 

 

Valid value ranges from 2 to 10. 2 (seconds) is the

 

 

 

default value.

 

 

 

 

 

 

7

Connection Completion Timeout.

 

 

 

Valid value ranges from 0 (zero) to 255 seconds.

 

 

 

120 (seconds) is the default value.

 

 

 

 

 

 