Nortel Networks 40M2420 manual Cfg/pmirr/monport, Port-Mirroring Configuration

Models: 40M2420

1 382
Download 382 pages 56.7 Kb
Page 319
Image 319

Alteon OS Command Reference

/cfg/pmirr/monport

Port-Mirroring Configuration

[Port EXT1 Menu]

add

- Add "Mirrored" port and VLANs

rem

- Rem "Mirrored" port and VLANs

delete

- Delete this "Monitor" port

cur

- Display current Port Mirroring configuration

Table 6-115Port Mirroring Monitor Port Menu Options (/cfg/pmirr/monport)

Command Syntax and Usage

add <mirrored port (port to mirror from)> <direction (in, out, or both)>

Adds the port to be mirrored. This command also allows you to enter the direction of the traffic. It is necessary to specify the direction because:

If the source port of the frame matches the mirrored port and the mirrored direction is ingress or both (ingress and egress), the frame is sent to the mirrored port.

If the destination port of the frame matches the mirrored port and the mirrored direction is egress or both, the frame is sent to the monitoring port.

rem <mirrored port (port to mirror from)>

Removes the mirrored port.

delete

Deletes this monitor port.

cur

Displays the current settings of the monitoring port.

40M2420, April 2007

Chapter 6: The Configuration Menu „ 319

Page 319
Image 319
Nortel Networks 40M2420 manual Cfg/pmirr/monport, Port-Mirroring Configuration, Rem mirrored port port to mirror from