120Chapter 11 Installing the analog terminal adapter

Figure 50 ATA2 back view

Mounting keyhole slots

Test insertion loss measurement

The maximum loss for ATA2 to Central Office (CO) configuration must not exceed 10 dB (see Figure 51 on page 120).

Figure 51 Insertion loss from the CO to the analog telephone

BCM50

ATA2

Analog telephone

Central

 

 

Office

 

 

 

 

Cable loss

 

BCM50 to ATA2

 

ATA2 to BCM50

 

 

 

10 dB Max

 

Longitudinal balance to ground

50 dB

 

60 to 4,000 Hz

 

With IEEE 455-1976 test

 

 

Overload level

3 dB

 

 

Measure the total insertion loss between the CO and analog device by using standard dial up test lines with a transmission test set. For example, Hewlett-Packard 4935A Transmission Test Set.

To measure the insertion loss from the CO to the analog device

1Establish a connection to the 1 mW, 1 kHz, CO service line with an analog telephone attached to the ATA2.

2Ensure that the analog port terminates correctly in 600 ohms:

• Replace the analog telephone with the test set

N0027152 01

Page 120