Chapter 11

Installing the analog terminal adapter 119

Figure 49 ATA2 pin outs

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Line jack

Terminal jack

 

 

 

 

 

 

 

 

 

 

TCM*

 

 

 

 

Ring (B-Lead)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TCM*

 

 

 

 

Tip (A-Lead)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* The TCM input is not polarity sensitive.

To connect the ATA2

1Connect one end of a line cord to the ATA2 terminal jack.

2Connect the other end to your telephone, modem, or fax.

3Connect one end of a line cord to the ATA2 line jack.

4Connect the other end to an available station port on the BCM50 system.

5For a 120 V or 230 V system, plug the DIN connector of the power supply cord into the power supply connector receptacle. Plug the adapter into a standard ac outlet.

Caution: In North America, the ATA2 must be powered from a Class 2 power source that is UL- and CSA-approved.

In Europe, the ATA2 must be powered from a Class II power source that is CE marked.

Mounting the ATA2

After the ATA2 is correctly connected, you can mount the unit on a wall, as described in this section.

To mount the ATA2 on a wall

1When using 0.5 mm wire (24 AWG), select a location within 800 m (2600 ft.) of the BCM50.

2Allow 12.5 cm (5 in.) clearance for the line jack, terminal jack, and power supply connector.

3Screw two 4-mm (#8) screws into the wall, 130 mm (5 1/4 in.) away from each other. Leave 6 mm (1/4 in.) of the two screws showing.

4Align the slots at the back of the ATA2 unit over the screws. Push the unit against the wall. The line jack, terminal jack, and power supply connector must be at the top of the ATA2 (see Figure 50).

BCM50 Installation and Maintenance Guide