Chapter 11 Installing the analog terminal adapter 121

Use RECEIVE/600 OHM/HOLD mode on the test set

3Ensure that the test set connects in parallel to the service line before removing the analog telephone or the line drops.

4Remove the single-line telephone.

5Measure the 1 kHz tone at the far end of the analog port, which is where the analog loop ends and where the analog device connects.

Note: The tone must be greater than - 10 dB (for example: - 9 dB is acceptable).

To measure the insertion loss from the analog device to the CO

1Establish a connection to a silent termination on the CO service line with an analog telephone attached to the ATA2.

2Make sure the analog port terminates correctly in 600 ohms by:

Replace the analog telephone with the test set

Use TRANSMIT/600 OHM/HOLD mode on the test set

3Make sure the test set connects in parallel to the service line before removing the analog telephone or the line drops.

4Remove the analog telephone.

5Introduce a 1 kHz tone into the analog line at - 10 dBm, and measure the level at the CO exchange.

Note: The difference in levels is the transmit loss and must be less than 10 dB (for example, 9 dB is acceptable).

Configuring the ATA2

Configure the ATA2 using Element Manager or Telset Administration. For detailed configuration information, refer to the BCM50 Device Configuration Guide (N0027146).