46Chapter 2 Introducing the BCM50 hardware

Table 5 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 2 of 2)

Specification

ATA2

ASM8

ASM8+

GASM

GASI

 

 

 

 

 

 

Analog loop resistance

200 ohms (1231

250 ohms (1538

200 ohms (1231

200 ohms (1231

200 ohms (1231

on terminal side for

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

data applications

wire or 4000 ft of

wire or 5000 ft of

wire or 4000 ft of

wire or 4000 ft of

wire or 4000 ft of

(cable only)

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

 

 

 

 

 

 

Input impedance at tip

600 ohms

600 ohms

600 ohms

600 ohms

600 ohms

and ring

 

 

 

 

 

 

 

 

 

 

 

Return loss

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

> 20 dB for 200

 

to 3400 Hz

to 3400 Hz

to 3400 Hz

to 3400 Hz

to 3400 Hz

 

(when

(when

(when

(when

(when

 

terminated with

terminated with

terminated with

terminated with

terminated with

 

600 ohms)

600 ohms)

600 ohms)

600 ohms)

600 ohms)

 

 

 

 

 

 

Insertion loss on an

ATA2 to BCM50

ATA2 to BCM50

ATA2 to BCM50

ATA2 to BCM50

ATA2 to BCM50

internal call

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

loss 3.0 dB ± 0.5

 

dB

dB

dB

dB

dB

 

 

 

 

 

 

Insertion loss on an

ATA2 to BCM50

ASM to BCM50

ASM to BCM50

ASM to BCM50

ASM to BCM50

external call

loss 2.2 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

loss 3.0 dB +/-

 

1.0 dB; BCM50

1.0 dB; BCM50

1.0 dB; BCM50

1.0 dB; BCM50

1.0 dB; BCM50

 

to ATA2 loss 0.5

to ASM loss 0.5

to ASM loss 0.5

to ASM loss 0.5

to ASM loss 0.5

 

dB ± 1.0 dB

dB ± 1.0 dB

dB ± 1.0 dB

dB ± 1.0 dB

dB ± 1.0 dB

 

 

 

 

 

 

MWI type (see Note)

Stutter tone

Stutter tone

Stutter tone/

Stutter tone/

Stutter Tone/

 

 

 

/ Voltage MWI

Reverse polarity/

Reverse polarity/

 

 

 

(CO: 120 V)

Voltage MWI

Voltage MWI

 

 

 

 

(CO: 120 V)

(PBX: 90 V)

 

 

 

 

 

 

Disconnect

N/A

N/A

OSI EIA/TIA 464

OSI EIA/TIA 464

N/A

supervision types

 

 

section

section

 

 

 

 

4.5.10.2.4/

4.5.10.2.4/

 

 

 

 

4.5.10.2.5.1

4.5.10.2.5.1

 

 

 

 

 

 

 

Note: The MWI type depends on the country profile, and the MWI voltage shown is a maximum value.

BCM50 hardware

The following BCM50 hardware items simplify the setup and connection of the system:

“Rackmount shelf”

“Wallmount bracket” on page 47

“Patch panel” on page 47

“Wiring field card (WFC)” on page 48

Rackmount shelf

To rackmount a BCM50 unit (main unit or expansion unit), you need a rackmount shelf. The rackmount shelf mounts in a standard 19-inch equipment rack. The BCM50 unit then clips into the tabs on the rackmount shelf. These tabs prevent the unit from sliding around or falling off the shelf.

N0027152 01

Page 46
Image 46
Nortel Networks manual BCM50 hardware, Rackmount shelf