176Chapter 21 Replacing a main unit

To remove a desktop mounted main unit

1Ensure that all of the cables are removed from the main unit. If they are not, refer to “To disconnect the cables” on page 174.

2If there is a unit mounted to the top of the main unit, slide that unit forward until it disengages from the clips on the main unit. Lift the unit off of the top of the main unit.

3Lift the main unit off of the table and set it on a flat, clean, static-free surface.

4Continue to the next step, “To install the BCM50 unit on a desktop or shelf” on page 89.

Installing the new main unit

Use one of the following procedures to install the new BCM50 main unit:

“Installing the BCM50 unit on the rackmount shelf” on page 81

“To install the BCM50 unit on the wallmount bracket” on page 86

“To install the BCM50 unit on a desktop or shelf” on page 89

After installing the new BCM50 main unit proceed to the procedure “To connect the cables”.

To connect the cables

1Insert the power supply retention clip into the new main unit.

2Rotate the power supply retention clip so that the power supply jack is clear.

3Connect the power supply cord to the main unit.

4Rotate the power supply retention clip to lock the power supply cord in place.

5Connect to ac power source:

a If the system has a UPS, connect the USB cable to the USB port on the main unit and plug the UPS power cord into the ac power source (wall outlet).

b If the system does not have a UPS, plug the power supply cable into the ac power source (wall outlet).

6If the system uses the external Music Source port, connect the music source cable to the Music Source port on the main unit.

7Connect the expansion cables or LAN cables to the expansion ports on the main unit. For expansion cables, make sure you connect the cables to the expansion ports from which they were removed. This ensures the same line and extension numbering.

8If the main unit is a BCM50a or BCM50e, connect the Ethernet cable or ADSL line to the WAN port and the Ethernet cables to the Router card LAN ports.

N0027152 01

Page 176
Image 176
Nortel Networks BCM50 manual Installing the new main unit, To remove a desktop mounted main unit, To connect the cables