166Chapter 18 Testing basic BCM50 functionality

Table 32 Level 1 reset

Step

User action

Power LED

Status LED

System state

Alternative user action

 

 

 

 

 

 

 

 

Solid yellow

Solid yellow

Power self-test

 

1

 

 

 

 

No action – system

Boot the system

Solid yellow

Off

Power self-test

remains off

 

 

 

 

 

 

 

Flashing yellow

Solid yellow

Ready for reset input

 

 

Press reset switch

Solid red

Flashing yellow

Request Level 1 reset

Do not press reset

2

switch – system boots

 

 

 

 

normally

 

Wait five seconds

Flashing red

Flashing yellow

Awaiting Level 1 reset

Press reset switch –

3

confirmation

system proceeds to

 

 

 

Level 2 reset

 

 

 

 

 

 

 

 

System performs

 

 

 

Solid red

Solid yellow

Level 1 reset

 

 

 

All configuration

Do not press reset

4

 

 

 

Press reset switch

 

 

programming erased.

switch – system boots

 

 

 

 

 

normally

 

 

 

 

System has rebooted,

 

 

Solid green

Solid green

and is ready for user

 

 

 

 

 

action.

 

 

 

 

 

 

 

Table 33 Level 2 reset

Step

User action

Power LED

Status LED

System state

Alternative user action

 

 

 

 

 

 

 

 

Solid yellow

Solid yellow

Power self-test

 

1

 

 

 

 

No action – system

Boot up the system

Solid yellow

Off

Power self-test

remains off

 

 

 

 

 

 

 

Flashing yellow

Solid yellow

Ready for reset input

 

 

Press reset switch

Solid red

Flashing yellow

Request Level 1 reset

Do not press reset

2

switch – system boots

 

 

 

 

normally

 

Press reset switch

 

 

 

Do not press reset

 

again within five

Solid red

Flashing red

Request Level 2 reset

 

switch – system remains

 

seconds of the first

3

button press.

 

 

 

in Level 1 reset state

 

 

 

 

 

 

 

 

Awaiting Level 2 reset

Press reset switch –

 

Wait five seconds

Flashing red

Flashing red

system proceeds to

 

confirmation

Nortel factory mode (do

4

 

 

 

 

 

 

 

not use)

 

 

 

 

System performs

 

 

 

 

 

Level 2 reset – All

 

 

 

Solid red

Solid red

configuration

 

 

 

programming and

Do not press reset

 

 

 

 

 

 

 

 

software updates

5

Press reset switch

 

 

switch – system boots

 

 

erased.

 

 

 

normally

 

 

 

 

 

 

 

 

 

System has rebooted,

 

 

 

Solid green

Solid green

and is ready for user

 

 

 

 

 

action.

 

 

 

 

 

 

 

N0027152 01

Page 166
Image 166
Nortel Networks manual Testing basic BCM50 functionality Level 1 reset, Level 2 reset