Nortel Networks BCM50 manual Verifying the media bay module switch settings

Models: BCM50

1 246
Download 246 pages 27.36 Kb
Page 93
Image 93

Chapter 8 Installing an expansion unit 93

Verifying the media bay module switch settings

Each MBM has dip switches on the back or underside of the module (see Figure 40).

Figure 40 Switches on the media bay module (not applicable for GASM or GATM)

Underside of the media bay module

6

5

4

3

2

1

Off

On

Module is

On 1 2 3 4 5 6 right-side up

dip switches

Back of the media bay module

Off

Rear view of the media bay module

Note: The GASM and GATM MBMs have a different dip switch configuration than shown in Figure 40. Refer to “To set GASM dip switches” on page 94 and “To set GATM dip switches” on page 94 for more information.

Verify that the dip switches for your MBMs are in the default factory positions as follows:

If you are installing a DTM, BRIM, 4x16, DSM16, DSM32, or ASM8, ensure that all the switches are on. This is the default setting for the MBM switches. After you have set the switches, proceed to “Installing a media bay module in an expansion unit” on page 95.

Caution: The MBM dip switches must remain in their default factory position. Any required modifications to the MBM settings are made through the software.

BCM50 Installation and Maintenance Guide

Page 93
Image 93
Nortel Networks BCM50 manual Verifying the media bay module switch settings