Chapter 2 Introducing the BCM50 hardware 45

Figure 12 GASM faceplate LEDs and connectors

The ringer equivalency number (REN) (per port) for ASM8 is 1; the REN for ASM8+ and GASM is 2.

Note: The termination of the analog interface can consist of any combination of devices, subject only to the requirement that the sum of the RENs of all the devices does not exceed the REN of the interface to which the device is connected.

Table 5 shows the specifications for ATA2, ASM8, GASM, and GASI.

Table 5 ATA2, ASM8, ASM8+, GASM, and GASI analog device specifications (Sheet 1 of 2)

Specification

ATA2

ASM8

ASM8+

GASM

GASI

 

 

 

 

 

 

Ringing frequency

20 Hz ± 1 Hz

20 Hz ± 1 Hz

20 Hz ±1 Hz

20 Hz ±1 Hz

20 Hz ±1 Hz

(North America)

 

 

 

 

 

 

 

 

 

 

 

Ringing frequency

25 Hz ± 1 Hz

25 Hz ± 1 Hz

25 Hz ± 1 Hz

25 Hz ± 1 Hz

25 Hz ± 1 Hz

(Europe)

 

 

 

 

 

 

 

 

 

 

 

Ringing voltage (North

80 V rms ± 10%

55 V rms ± 10%

65 V rms ± 10%

65 V rms ± 10%

65 V rms ± 10%

America)

 

 

 

 

 

 

 

 

 

 

 

Ringing voltage

75 V rms +/-

N/A

65 V rms ± 10%

65 V rms ± 10%

65 V rms ± 10%

(Europe)

10%

 

 

 

 

 

 

 

 

 

 

Loop current

20 mA minimum

20 mA minimum

20 mA minimum

20 mA minimum

20 mA minimum

 

 

 

 

 

 

Battery feed voltage

-48 V dc ± 10%

-48 V dc ± 10%

-29 V dc ± 10%

-48 V dc ± 10%

-48 V dc ± 10%

 

 

 

 

 

 

FIC code

OL13ABC

N/A

N/A

N/A

N/A

 

 

 

 

 

 

Ringer equivalency

3

1

2

2

2

number

 

 

 

 

 

 

 

 

 

 

 

ATA2 to BCM50 loop

135 ohms

N/A

N/A

N/A

N/A

resistance (cable only)

(800 m of

 

 

 

 

 

0.5-mm wire or

 

 

 

 

 

2600 ft of 24

 

 

 

 

 

AWG wire)

 

 

 

 

 

 

 

 

 

 

Analog loop resistance

1300 ohms

250 ohms (1538

200 ohms (1231

200 ohms (1231

200 ohms (1231

on terminal side for

(7200 m of

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

m of 0.5-mm

voice applications

0.5-mm wire or

wire or 5000 ft of

wire or 4000 ft of

wire or 4000 ft of

wire or 4000 ft of

(cable only)

26000 ft of 24

24 AWG wire)

24 AWG wire)

24 AWG wire)

24 AWG wire)

 

AWG wire)

 

 

 

 

 

 

 

 

 

 