Chapter 5 Configuring the R2MFC MBM 53

3Select the appropriate Bus # under Configuration > Resources > Telephony Resources in the navigation tree.

The Bus # information frame displays. See Figure 19 for an example of the screen layout for an R2MFC MBM configured on Bus 2.0.

Figure 19 BCM Bus configuration for R2MFC MBM

4Configure the fields in the Details for Module: 2.0 panel. See Table 7 for parameters and settings.

Table 7 Module configuration parameters

Parameter

Setting

 

 

Trunk type

PRI

 

 

Protocol

Euro

 

 

Clock source

Primary external (if only one

 

trunk module in system;

 

otherwise, it depends on the

 

synchronization scheme of

 

the BCM)

 

 

Overlap receiving

Selected (On)

 

 

Local number length

According to BCM local

 

dialing plan (customer -

 

dependent)

 

Note: This field appears

 

only when the Overlap

 

receiving field is selected.

 

 

E1 Parameters - CRC4

Not Selected (Off)

 

 

R2MFC Media Bay Module Installation and Configuration Guide

Page 53
Image 53
Nortel Networks R2MFC manual Module configuration parameters, Parameter Setting