Configuring DIP switch settings and definitions 105

Table 42 Interpretation of transmitted MFC signals (Sheet 2 of 2)

Meaning

Signal

Meaning

Signal

Meaning

Signal

 

 

 

 

 

 

BW_OutOfOrder

B_8

FW_Digit_13

I_13

FW_Categ_15

II_15

 

 

 

 

 

 

BW_ChangOrder

B_4

FW_Digit_14

I_14

FW_KD_Local

II_3

 

 

 

 

 

 

FW_ReqFault

I_12

FW_Digit_15

I_15

FW_KD_LnDst

II_2

 

 

 

 

 

 

FW_EndDigits

I_15

FW_Categ_1

II_1

 

 

 

 

 

 

 

 

Chile Config 1

E1 Physical Characteristics

Connector type: BNC

Line coding: HDB3

E1 Framing

Frame mode: Alternate

Register signaling

Regret option: OFF

End of dialing (Incoming): terminated by indication from destination switch, or by MFC forward signal FW_EndDigits

End of dialing (Outgoing): terminated by indication from destination switch, or by MFC forward signal FW_EndDigits

R2 line signaling

Chile Config 1 R2 signals are according to CCITT standard. See Table 28 for the Chile Config 1 R2 signal definitions.

Table 43 Chile Config 1 R2 A/B signals

Forward

 

 

 

Backward

 

 

 

 

 

 

 

 

 

Signal

A

B

 

Signal

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

1

0

 

Idle

1

0

 

 

 

 

 

 

 

Seize

0

0

 

Seize acknowledge

1

1

 

 

 

 

 

 

 

Clear forward

1

0

 

Answer

0

1

 

 

 

 

 

 

 

 

 

 

 

Clear back

1

1

 

 

 

 

 

 

 

R2MFC Media Bay Module Installation and Configuration Guide

Page 105
Image 105
Nortel Networks R2MFC manual Chile Config 1 R2 A/B signals