Configuring DIP switch settings and definitions 107
Table 45 Interpretation of transmitted MFC signals
Meaning | Signal | Meaning | Signal | Meaning | Signal |
|
|
|
|
|
|
BW_NextDig | A_1 | FW_ReqFault | I_12 | FW_Categ_1 | II_1 |
|
|
|
|
|
|
BW_BCateg | A_3 | FW_EndDigits | I_15 | FW_Categ_2 | II_2 |
|
|
|
|
|
|
BW_RtrnToA | A_1 | FW_EndANIdgts | I_15 | FW_Categ_3 | II_3 |
|
|
|
|
|
|
BW_A_Congest | A_4 | FW_Digit_1 | I_1 | FW_Categ_4 | II_4 |
|
|
|
|
|
|
BW_B_Congest | B_4 | FW_Digit_2 | I_2 | FW_Categ_5 | II_5 |
|
|
|
|
|
|
BW_Category | A_5 | FW_Digit_3 | I_3 | FW_Categ_6 | II_6 |
|
|
|
|
|
|
BW_SpeechChrg | A_6 | FW_Digit_4 | I_4 | FW_Categ_7 | II_7 |
|
|
|
|
|
|
BW_OrigDn | A_5 | FW_Digit_5 | I_5 | FW_Categ_8 | II_8 |
|
|
|
|
|
|
BW_FreeCharge | B_6 | FW_Digit_6 | I_6 | FW_Categ_9 | II_9 |
|
|
|
|
|
|
BW_FreeNoChrg | B_7 | FW_Digit_7 | I_7 | FW_Categ_10 | II_10 |
|
|
|
|
|
|
BW_CntrCharge | NO_SG | FW_Digit_8 | I_8 | FW_Categ_11 | II_11 |
|
|
|
|
|
|
BW_Busy | B_3 | FW_Digit_9 | I_9 | FW_Categ_12 | II_12 |
|
|
|
|
|
|
BW_Unlocated | B_5 | FW_Digit_10 | I_10 | FW_Categ_13 | II_13 |
|
|
|
|
|
|
BW_OutOfOrder | B_8 | FW_Digit_11 | I_11 | FW_Categ_14 | II_14 |
|
|
|
|
|
|
BW_ChangOrder | B_2 | FW_Digit_12 | I_12 | FW_Categ_15 | II_15 |
|
|
|
|
|
|
|
| FW_Digit_13 | I_13 | FW_KD_Local | II_3 |
|
|
|
|
|
|
|
| FW_Digit_14 | I_14 | FW_KD_LnDst | II_2 |
|
|
|
|
|
|
|
| FW_Digit_15 | I_15 |
|
|
|
|
|
|
|
|
Panama Config 1
Panama is a supported country configuration. You select Panama by setting the Country Selection DIP switches to custom and configuring the settings manually through the CLI.