Chapter 2 Overview 23

System Status LEDs

The R2MFC MBM has three visual status monitor indicators on the left side of the faceplate. They are:

Power LED — This green LED indicates the status of power to the R2MFC MBM.

In Service LED — This green LED indicates the status of the E1 signal coming to the R2MFC MBM from the BCM.

Diag LED — This red LED indicates if the R2MFC MBM is in a diagnostic or loopback mode.

Config DIP switches

The R2MFC MBM has six config DIP switches on its faceplate. These DIP switches are used to set the following configurations for the R2MFC MBM:

country

problem diagnosis

second dial tone

DIP switches must be set before power is connected to the R2MFC MBM. Figure 3 shows the Config DIP switches.

Figure 3 Config DIP Switches

country configuration

second dial tone

 

 

 

 

 

N

 

 

 

 

 

O

6

5

4

3

2

1

6

5

4

3

2

1

ON

diagnostics

country

For DIP switch values and configuration information, see “Configuring the MFCR2 (external) link” on page 49.

These DIP switches are also used for problem diagnostics. For specific settings and uses, see “Diagnostic tools” on page 63.

R2MFC Media Bay Module Installation and Configuration Guide

Page 23
Image 23
Nortel Networks R2MFC manual System Status LEDs, Config DIP switches